Quantum Series Installation and Service Manual
No concentrate dis- pensed, water only
Excessive remnant left in empty concen- trate pouch
Concentrate refill light comes on prema- turely
Concentrate refill light does not come on at all
Dispense tube not fully engaged into recepta- cle on concentrate pouch
Dispense tube discon- nected from mixing chamber
Slide block on pump in open position
Switch on pump platform in FLUSH position
Concentrate too cold, not properly thawed
Defective pump motor
Concentrate pouch improp- erly thawed
Concentrate pouch and/or dispense tube improp- erly installed
Concentrate pouch improp- erly thawed
Concentrate pouch and/or dispense tube improp- erly installed
Loose wiring
Bad VRB board
Bad pump motor
Pump improperly locked or pump is open
Run/flush switch is in the FLUSH position
Refer to Concentrate Loading sec- tion of this manual
Refer to Concentrate Loading sec- tion of this manual
Close and lock the slide block. Refer to Concentrate Loading section of this manual
Move switch to RUN position
Concentrate should be 34oF
Replace pump motor
Concentrate should be 34oF
Refer to Concentrate Loading sec- tion of this manual
Concentrate should be 34oF
(1.1 oC
Refer to concentrate loading sec- tion of this manual
Check wiring connections between the pump motor and the VRB board
Replace VRB board
Replace pump motor
Close and lock Pump
Move switch to the RUN position
720901120 | - 14 - |