User Manual

UMN:CLI

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

 

 

8.5.1Configuring Rate Limit

To set a port bandwidth, use the following command.

Command

 

Mode

Description

 

 

 

 

rate PORTS RATE [egress

in-

 

Sets port bandwidth. If you input egress or ingress, you

 

can configure outgoing packet or incoming packet. The

gress]

 

 

 

 

unit is 64 Kbps.

 

 

Bridge

 

 

 

no rate PORTS

 

Clears rate configuration of a specific port.

 

 

 

 

 

 

no rate PORTS [egress ingress]

 

Clears rate configuration of a specific port by transmit-

 

ting direction.

 

 

 

 

 

 

 

Unless you input neither egress nor ingress, they are configured to be same. To switch, egress is incoming packet. To display the configured bandwidth, use the following com- mand.

Command

Mode

Description

 

 

 

show rate

Global

Shows the configured bandwidth.

 

 

 

8.5.2Sample Configuration

The following is an example of showing the configuration after setting the bandwidth of 64Mbps to port number 1 and 128Mbps to the port number 2.

SWTICH(bridge)# rate 1 64 SWTICH(bridge)# rate 2 128 SWTICH(bridge)# show rate unit : kbps E : Enhanced

------------------------------------------------------------------------------

Port

Ingress

Egress

Port

Ingress

Egress

------------------------------------------

 

 

 

 

 

 

+-----------------------------------

 

1

64

64

2

128

128

3

N/A

N/A

4

N/A

N/A

5

N/A

N/A

6

N/A

N/A

7

N/A

N/A

8

N/A

N/A

SWTICH(bridge)#

A50010-Y3-C150-2-7619

235

Page 235
Image 235
Siemens S223, S323 Configuring Rate Limit, To set a port bandwidth, use the following command, A50010-Y3-C150-2-7619 235