UMN:CLI

User Manual

 

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

The Query Interval of IGMP v2 Snooping Querier

To configure a query interval of the querier, use the following command.

Command

 

Mode

Description

 

 

 

 

 

 

 

Configures the IGMP snooping querier query interval

ip igmp snooping querier query-

 

on the system.

interval <1-1800>

 

 

1-1800: IGMP snooping querier query interval in sec-

 

 

Global

onds

 

 

 

 

ip igmp snooping vlan

VLANS

 

Enables the IGMP snooping querier on a VLAN inter-

 

face.

querier query-interval <1-1800>

 

 

VLANS: VLAN ID

 

 

 

 

 

 

 

To disable the query interval of the querier, use the following command.

Command

 

Mode

Description

 

 

 

 

no ip igmp snooping

querier

 

Disables the IGMP snooping querier interval.

query-interval

 

 

 

Global

 

 

 

 

no ip igmp snooping vlan

Disables the IGMP snooping querier interval on a

 

VLANS querier query-interval

 

VLAN interface.

 

 

 

 

The Timeout Value of IGMP v2 Snooping Querier’s General Query

Use this following command to configure the max response time in which the reply for the IGMP snooping query being sent should be received.

Command

Mode

Description

 

 

 

ip igmp snooping querier max-

 

Configures the IGMP snooping max-response-time

 

interval on the system.

response-time <1-25>

 

 

1-25: The maximum response time in seconds

 

Global

 

 

ip igmp snooping vlan VLANS

Enables the IGMP snooping max-response-time on a

 

querier max-response-time <1-

 

VLAN interface.

25>

 

VLANS: VLAN ID

 

 

 

To disable the max-response-time, use the following command.

 

Command

Mode

Description

 

 

 

no ip igmp snooping querier

 

Disables the IGMP snooping max-response-time inter-

max-response-time

 

val.

 

 

 

Global

 

no ip

igmp

snooping vlan

Disables the IGMP snooping max-response-time on a

VLANS

querier

max-response-

 

 

VLAN interface.

time

 

 

 

 

 

 

 

 

 

 

 

 