UMN:CLI

User Manual

 

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

always correct and there won't be any subsequent time jumps after the initial correction. Unlike NTP, SNTP usually uses just one Ethernet Time Server to calculate the time and then it "jumps" the system time to the calculated time. It can, however, have back-up Ethernet Time Servers in case one is not available.

To configure the switch in SNTP, use the following commands.

Command

Mode

Description

 

 

 

sntp SERVER 1 [SERVER 2]

 

Specifies the IP address of the SNTP server. It is pos-

 

sible up to three number of server.

[SERVER 3]

Global

SERVER: server IP address

 

 

 

 

 

no sntp

 

Disables SNTP function.

 

 

 

To display SNTP configuration, use the following command.

Command

Mode

Description

 

 

 

show sntp

Enable

Show SNTP configuration.

Global

 

 

 

 

 

The following is to register SNTP server as 203.255.112.96 and enable it.

SWITCH(config)# sntp 203.255.112.96 SWITCH(config)# show sntp

==========================

sntpd is running.

==========================

Time Servers

--------------------------

1st : 203.255.112.96

==========================

SWITCH(config)#

i

You can configure up to 3 servers so that you use second and third servers as backup use in case the first server is down.

6.1.7Terminal Configuration

By default, the hiD 6615 S223/S323 is configured to display 24 lines composed by 80 characters on console terminal. The maximum line displaying is 512 lines.

To set the number of line displaying on terminal screen, use the following command.

Command

Mode

Description

 

 

 

terminal length <0-512>

 

Sets the number of line displaying on console terminal,

Global

enter the value.

 

 

 

 

no terminal length

 

Restores a default line displaying.

 

 

 

86

A50010-Y3-C150-2-7619

Page 86
Image 86
Siemens S323, S223 user manual Terminal Configuration, To display Sntp configuration, use the following command, No sntp