Section 3 Operation

E1 Status / Configuration / Loopback

The status of the two E1 interfaces is displayed on this screen. Information such as alarm status, signaling, line coding, and CRC4 Detection framing type are shown. From this screen the E1 can be configured for a particular application by using the keyboard cursor keys to highlight the desired option and perform the change. A local or remote loopback may be activated or deactivated from this screen. The E1A Status Screen is illustrated in Figure 3-4, and the E1B Status Screen is illustrated in

Figure 3-5.

 

 

E1A STATUS/CONFIGURATION/LOOPBACK

 

 

RX ==>

----->>----

>>----

>>----

{

RF

}----

>>

---->>----

>>--+

==> TX

LOCAL

 

 

{/\/\/\/\}

 

REMOTE

TX <==

-----<<----

<<----

<<----

{

UP

}----

<<

----<<----

<<--+

X== RX

 

 

 

 

LOCAL TRACER

 

REMOTE TRACER

 

 

 

 

 

------------

 

 

-------------

 

 

E1 INTERFACE ALARMS:

UA1

RMT

LOS

 

UA1

LOS

 

 

 

 

 

OOF

CV

CRC

 

 

 

 

 

E1 INTERFACE TYPE:

120

OHM

 

 

75 OHM

 

 

 

ALARM REPORTING:

 

ENABLED

 

 

DISABLED

 

 

CRC4 DETECTION:

 

ENABLED

 

 

ENABLED

 

 

 

SIGNALING:

 

 

CAS

 

 

 

CAS

 

 

 

LINE CODE:

 

 

HDB3

 

 

 

HDB3

 

 

 

LOOP/NORMAL STATE:

NORMAL

 

 

NORMAL

 

 

(*)—INDICATES THAT SETTING DIFFERS FROM THE FRONT PANEL

===============================================================================

PRESS ‘M’ - MAIN MENU, ‘U’,’D’ - MOVE UP AND DOWN, [SPACE] - SELECT:

Figure 3-4. E1A Status Screen

 

 

E1B STATUS/CONFIGURATION/LOOPBACK

 

 

RX ==>

----->>----

>>----

>>----

{

RF

}----

>>

---->>----

>>--+

==> TX

LOCAL

 

 

{/\/\/\/\}

 

REMOTE

TX <==

-----<<----

<<----

<<----

{

UP

}----

<<

----<<----

<<--+

X== RX

 

 

 

 

LOCAL TRACER

 

REMOTE TRACER

 

 

 

 

 

------------

 

 

-------------

 

 

E1 INTERFACE ALARMS:

UA1

RMT

LOS

 

UA1

LOS

 

 

 

 

 

OOF

CV

CRC

 

 

 

 

 

E1 INTERFACE TYPE:

120

OHM

 

 

75 OHM

 

 

 

ALARM REPORTING:

 

ENABLED

 

 

DISABLED

 

 

CRC4 DETECTION:

 

ENABLED

 

 

ENABLED

 

 

 

SIGNALING:

 

 

CAS

 

 

 

CAS

 

 

 

LINE CODE:

 

 

HDB3

 

 

 

HDB3

 

 

 

LOOP/NORMAL STATE:

NORMAL

 

 

NORMAL

 

 

(*)—INDICATES THAT SETTING DIFFERS FROM THE FRONT PANEL

===============================================================================

PRESS ‘M’ - MAIN MENU, ‘U’,’D’ - MOVE UP AND DOWN, [SPACE] - SELECT:

Figure 3-5. E1B Status Screen

28

TRACER 2 x E1 User’s Manual