Section 2 Installation
E1 Interfaces
The E1 interface conforms to the ITU G.703 and G.704 electrical and signaling interfaces recommendations. Two interfacing configurations are available:
•75Ω unbalanced BNC coaxial connectors.
•120Ω balanced 15 pin / RJ48 connectors with the pinouts shown here.
15 Pin |
|
|
|
|
Pin | Function | Pin | Function | |
1 | E1 Out ring | 1 | E1 | Out ring |
2 | Frame ground | 2 | E1 | Out tip |
3 | E1 In ring | 3 | N.C. | |
4 | Frame ground | 4 | E1 | In ring |
5 | N.C. | 5 | E1 | In tip |
6 | N.C. | 6 | N.C. | |
7 | N.C. | 7 | N.C. | |
8 | N.C. | 8 | N.C. | |
9 | E1 Out tip |
|
|
|
10 | N.C. |
|
|
|
11 | E1 In tip |
|
|
|
12 | N.C. |
|
|
|
13 | N.C. |
|
|
|
14 | N.C. |
|
|
|
15 | N.C. |
|
|
|
The 75Ω unbalanced interface provides two pair of 75Ω BNC connectors. The shield of the OUT coaxial connection is attached to earth ground. A jumper is provided to optionally connect the shield of the INPUT coaxial connection to ground as described in G.703. This jumper is located on the inside of the E1 interface board, between each of the two BNC connectors. The E1 module must be removed to access this option.
The 120Ω balanced interface provides two individual 120Ω
TRACER 2 x E1 User’s Manual | 13 |