Section 3 Operation
MAIN MENU SELECTIONS
System Status Screen
The screen in Figure
TRACER SYSTEM STATUS
ELAPSED TIME: 00000 DAYS, 00:00:07
ADTRAN TECHNICAL | SUPPORT - | ||
|
| ||
E1A === C | / | RF UP | C === E1A |
S #(- | |||
E1B === U | \ | RF UP | U === E1B |
|
|
LOCAL | TRACER |
|
|
| REMOTE TRACER |
FREQ PLAN B | SITE: ADTRAN |
|
| FREQ PLAN A | |
MIN | NOM |
| MIN | NOM | |
|
| ||||
[###################_] |
|
| [###################_] | ||
| RX POWER | RFC LINK UP: | YES |
| RX POWER |
|
| CODE SYNC: | YES |
|
|
MIN | MAX | CARRIER SYNC: | YES | MIN | MAX |
[####################] | E1 MUX SYNC: | YES | [####################] | ||
| TX POWER | CHIPPING CODE: | 0 |
| TX POWER |
=============================================================================
PRESS ‘M’ - MAIN MENU:
Figure 3-1. System Status Screen
The upper portion of the screen indicates how long the system has been running since the last reset operation. The “E1A” and “E1B” labels will be highlighted if any error conditions exist on that E1 interface.
The status of the radio link is indicated as Up or Down. The left portion of the screen reports the status of the local system (the system to which the terminal is attached); the right portion reports the status of the remote system. The approximate transmitter and receiver signal levels are shown via the bar graphs. If the link is down and remote end data is unavailable, the bar graphs will show
26 | TRACER 2 x E1 User’s Manual |