Section 4 Troubleshooting
I M P O R T A N T
If problems persist after you have followed the Recommended Actions, contact ADTRAN Technical Support at (011)
“Fail” Light is Lit After Pressing “Remote Test” Button
The Remote Fail light will activate after a Remote Test has failed.
| Recommended Action | |
Possible Cause | (see list below) | |
• | The | .................. 1 |
• | The RX power may be below the specified receiver sensitivity | 1 |
Recommended Actions:
1.Verify that the “RF Low” light is off.
“RF Low” Light is On
This alarm will activate if the RX power is below approximately
| Recommended Action |
Possible Cause | (see list below) |
• The RX power is below approximately | |
• The | |
• The RF path is not aligned | 3,8 |
• Water is in the antenna feedhorn or connectors | 4,8 |
Recommended Actions:.
1.Check the
2.Check the RF path using a spectrum analyzer or RSSI voltages for proper alignment. Have path professionally
3.Check the antenna feedhorn and all outdoor connections for water.
4.Check all connections between the BBP, the RFC, and the antenna.
5.Check the IF and RF cables for shorts.
6.Check the connections inside the mastmount or rackmount RFC.
7.Replace the RFC.
36 | TRACER 2 x E1 User’s Manual |