UMN:CLI

User Manual

 

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

In this time, if there is no answer from receiver for configured time, the router trans- mits LSA again. Retransmit-interval is configuration of the time interval between transmission and retransmission

Dead-interval

If there is no hello packet for the configured time. The router perceives other router is stopped working. Dead-interval is configuration of the time interval which perceives other router is stopped operating.

Transmit-delay

When a router transmits LSA, the traffic can be delayed by status of communications. Transmit-delay is considering of the configuration for LSA transmission time.

Configuration for virtual link can be selected more than 2 options without order. The fol- lowing is explaining options of command:

authentication [message-digest null]

authentication-key KEY

message-digest-key KEY md5 KEY

hello-interval <1-65535>

retransmit-interval <1-65535>

dead-interval <1-65535>

transmit-delay <1-65535>

To configure a virtual link with one option, use the following command.

Command

Mode

Description

 

 

 

area <0-4294967295>virtual-link A.B.C.D au-

 

 

thentication [message-digest null]

 

 

 

 

 

area <0-4294967295>virtual-link A.B.C.D au-

 

 

thentication-key KEY

 

 

 

 

 

area <0-4294967295>virtual-link A.B.C.D mes-

 

 

sage-digest-key KEY md5 KEY

 

 

 

 

 

area <0-4294967295>virtual-link A.B.C.D hello-

Router

Configures a virtual link.

interval <1-65535>

 

 

 

 

 

area <0-4294967295>virtual-link A.B.C.D re-

 

 

transmit-interval <1-65535>

 

 

 

 

 

area <0-4294967295>virtual-link A.B.C.D dead-

 

 

interval <1-65535>

 

 

 

 

 

area <0-4294967295>virtual-link A.B.C.D

 

 

transmit-delay <1-65535>

 

 

 

 

 

The following example shows how to configure virtual link with more than 2 options:

area <0-4294967295>virtual-link A.B.C.D authentication-key KEY authentication [message-digest null]

area <0-4294967295>virtual-link A.B.C.D hello-interval <1-65,535>dead-interval <1-65535>

348

A50010-Y3-C150-2-7619

Page 348
Image 348
Siemens S323, S223 user manual Dead-interval, Transmit-delay, 348 A50010-Y3-C150-2-7619