User Manual

UMN:CLI

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

 

 

7.4.2RMON Alarm

There are two ways to compare with the threshold: absolute comparison and delta com- parison.

Absolute Comparison: Comparing sample data with the threshold at configured in- terval, if the data is more than the threshold or less than it, alarm is occurred

Delta Comparison: Comparing difference between current data and the latest data with the threshold, if the data is more than the threshold or less than it, alarm is oc- curred.

You need to open RMON Alarm Configuration mode first to configure RMON alarm.

Command

Mode

Description

 

 

 

rmon-alarm <1-65535>

Global

Opens RMON Alarm Configuration mode.

1-65535: index number

 

 

 

 

 

The following is an example of listing available commands on RMON-alarm Configuration mode.

SWITCH(config)# rmon-alarm1

SWITCH(config-rmonalarm[1])# ?

RMON alarm configuration commands:

active

Activate the event

do

To run

exec commands in config mode

exit

End current mode and down to previous mode

falling-event

Associate the falling threshold with an existing RMON

 

event

 

falling-threshold

Define

the falling threshold

help

Description of the interactive help system

owner

Assign

the owner who define and is using the history

resources

 

 

rising-event

Associate the rising threshold with an existing RMON

 

event

 

rising-threshold

Define

the rising threshold

sample-interval

Specify the sampling interval for RMON alarm

sample-type

Define

the sampling type

sample-variable

Define

the MIB Object for sample variable

show

Show running system information

startup-type

Define

startup alarm type (default : rising)

write

Write running configuration to memory or terminal

SWITCH(config-rmonalarm[1])#

7.4.2.1Subject of RMON Alarm

User needs to configure RMON alarm and identify subject using many kinds of data from alarm. To identify subject of alarm, use the following command.

Command

Mode

Description

 

 

 

owner NAME

RMON

Identifies subject using related data, enter the name

(max. 32 characters).

 

 

 

 

 

A50010-Y3-C150-2-7619

129

Page 129
Image 129
Siemens S223, S323 user manual Subject of Rmon Alarm, A50010-Y3-C150-2-7619 129, Command Mode Description Rmon-alarm