Siemens S223, S323 user manual Port Traffic, Fan Operation, Mode Description Threshold Port

Models: S323 S223

1 381
Download 381 pages 49.11 Kb
Page 89
Image 89

User Manual

UMN:CLI

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

 

 

To show a configured threshold of CPU load, use the following command.

Command

Mode

Description

 

 

 

show cpuload

All

Shows a configured threshold of CPU load.

 

 

 

6.1.12.2Port Traffic

To set a threshold of port traffic, use the following command.

Command

 

Mode

Description

 

 

 

 

 

threshold

port

PORTS

 

Sets a threshold of port traffic.

 

PORTS: port number (1/1, 1/2, 2/1, …)

THRESHOLD {5 60

600} {rx

 

 

THRESHOLD: threshold value (unit: kbps)

tx}

 

 

Global

 

 

5 60 600: time Interval (unit: second)

 

 

 

 

 

 

 

 

no threshold

port PORTS {rx

 

Deletes a configured threshold of port traffic.

tx}

 

 

 

 

 

 

 

 

 

 

 

 

i

The threshold of the port is set to the maximum rate of the port as a default.

To show a configured threshold of port traffic, use the following command.

Command

Mode

Description

 

 

 

show port threshold

Enable

Shows a configured threshold of port traffic.

Global

 

 

 

 

 

6.1.12.3Fan Operation

The system fan will operate depending on a configured fan threshold. To set a threshold of port traffic, use the following command.

Command

Mode

Description

 

 

 

 

 

Sets a threshold of fan operation in the unit of centi-

threshold fan START-TEMP

 

grade (°C).

STOP-TEMP

Global

START-TEMP: starts fan operation. (default: 30)

 

 

STOP-TEMP: stops fan operation. (default: 0)

 

 

 

no threshold fan

 

Deletes a configured threshold of fan operation.

 

 

 

When you set a threshold of fan operation, START-TEMPmust be higher than STOP-

! TEMP.

To show a configured threshold of fan operation, use the following command.

Command

Mode

Description

 

 

 

show status fan

Enable /Global / Bridge

Shows a status and configured threshold of fan opera-

tion.

 

 

 

 

 

A50010-Y3-C150-2-7619

89

Page 89