Siemens S223, S323 user manual Identifying Member Ports within Lacp, Bpdu Transmission Rate

Models: S323 S223

1 381
Download 381 pages 49.11 Kb
Page 197
Image 197

User Manual

UMN:CLI

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

 

 

8.2.2.4Identifying Member Ports within LACP

The port configured as member port is basically configured to aggregate to LACP. How- ever, even though the configuration as member port is not released, they could operate as independent port without being aggregated to LACP. These independent ports cannot be configured as trunk port because they are independent from being aggregated to LACP under the condition of being configured as member port.

To configure member port to aggregate to LACP, use the following command.

Command

 

Mode

Description

 

 

 

 

lacp port aggregation

PORTS

 

Designates whether a member port joins LACP or not,

Bridge

select the member port should be included. (default:

{aggregatable individual}

 

aggregatable)

 

 

 

 

 

 

 

To clear aggregated to LACP of configured member port, use the following command.

Command

Mode

Description

 

 

 

no lacp port aggregation PORTS

Bridge

Deletes the configured member port in LACP, select

the member port.

 

 

 

 

 

8.2.2.5BPDU Transmission Rate

Member port transmits BPDU with its information. For the hiD 6615 S223/S323, it is pos- sible to configure the BPDU transmission rate, use the following command.

Command

Mode

Description

 

 

 

 

 

Configures BPDU transmission rate:

lacp port timeout PORTS {short

Bridge

PORTS: select the port number.

long}

short: fast rate (once every 1 sec)

 

 

 

long: slow rate (30 sec: default)

 

 

 

To clear BPDU transmission rate, use the following command (clear means long timeout).

Command

Mode

Description

 

 

 

no lacp port timeout PORTS

Bridge

Deletes BPDU transmission rate of configured member

port, select the port number.

 

 

 

 

 

8.2.2.6Key value of Member Port

Member port of LACP has key value. All member ports in one aggregator have same key values. To make an aggregator consisted of specified member ports, configure different key value with key value of another port.

Command

Mode

Description

 

 

 

lacp port admin-key PORTS <1-

 

Configures key value of member port:

Bridge

PORTS: select the port number.

15>

 

1-15: select the port key value. (default: 1)

 

 

 

 

 