Installing the 201i server in a large Meridian 1 system | Standard 1.07 |
Installing the 201i server in the large Meridian 1 switch
Introduction
The 201i server occupies two slots. You can install the 201i server in slots 0 through 14. Ensure that both slots have electrical backplane connectivity.
To position the 201i server on the switch shelf
1Ensure that no cables are connected to the slots in which you are installing the 201i server.
2Open the lock latches at the top and bottom of the 201i server faceplate.
Note: When you open the top lock latch, you break the yellow backplane warning label, if it has not been removed. You must move the secondary backplane connector before you install the 201i server. For details, see “Repositioning the secondary backplane connector” on page 50.
3Slide the 201i server into an unoccupied pair of slots.
Ensure that the 201i server is positioned correctly between the slots.
ATTENTION |
| |
Do not push the 201i server into place against the | ||
| ||
| backplane until you are ready to observe the startup | |
| cycle. | |
| The 201i server receives power and starts as soon as | |
| the 201i server makes contact with the switch | |
| backplane. |
4Connect the
56 | CallPilot |