Installing the 201i server in an Option 11C or Option 11C Mini

Standard 1.07

Installing the intermediate SCSI cable for Option 11C

Introduction

Before you can connect an external CD-ROM or tape drive to the 201i server, Option 11C requires an intermediate SCSI cable (NTRH1407).

Note: If you are installing the 201i server in an Option 11C Mini, go to page 86.

Cable description

The connector on the NTRH1407 cable that attaches to the 201i server faceplate is a low-profile right-angle connector. This allows the SCSI device to be permanently connected to the 201i server with the Option 11C cabinet cover on.

The SCSI device connector end is equipped with a bracket assembly. This bracket assembly attaches to the Option 11C below the card cage. The CD-ROM or tape drive connects to this bracket assembly with the NTRH3502 cable that is provided with the device.

78

CallPilot

Page 78
Image 78
Nortel Networks 201i manual Installing the intermediate Scsi cable for Option 11C, Cable description