Nortel Networks 201i manual Switch Eligible slots

Models: 201i

1 178
Download 178 pages 2.41 Kb
Page 72
Image 72

Installing the 201i server in an Option 11C or Option 11C Mini

Standard 1.07

Installing the 201i server in the Option 11C or Option 11C Mini switch

Introduction

The 201i server occupies physical and electrical slots. The 201i server must be installed in two peripheral equipment slots as follows:

Switch

Eligible slots

 

 

Option 11C

Slots 1 through 9

 

Note: Both of the server backplane connectors

 

must be installed in slots 1 through 9 to receive

 

proper power. Neither connector can reside in slot

 

10.

 

 

Option 11C Mini

A pair of consecutive slots in any cabinet

 

Note: You cannot install the 201i server in slots 0

 

or 4, because these slots are dedicated to other

 

cards. For more information about cards and slots,

 

refer to the Option 11C Mini documentation.

 

 

To position the 201i server on the switch shelf

1Remove the front panel of the switch.

Note: On the Option 11C Mini, do the following:

a.Loosen the spring-loaded clips.

b.Slide the cover to the left.

c.Pull the cover up to remove it from the cabinet.

72

CallPilot

Page 72
Image 72
Nortel Networks 201i manual Switch Eligible slots