SET UP BASE STATION

NOTE Install batteries in the remote sensor before the base station matching the polarities (+ and -).

For continuous use, please install the AC adapter. The batteries are for back-up use only.

NOTE Please make sure the socket-outlet is installed near the equipment and is easily accessible.

Install the base station batteries (4 x UM-3 / AA) matching the polarity + and -. Press RESET after each battery change.

NOTE Do not use rechargeable batteries. It is recommended that you use alkaline batteries with this product for longer performance.

The battery icon indicator may appear in the following areas:

AREA

MEANIN G

 

Weather Forecast

Battery in the base station is low.

Area

will show when AC adapter is

 

 

 

 

disconnected.

 

 

 

 

Temperature / Heat

The displayed channel indicates

 

Index / Wind Chill

 

the outdoor sensor for which

Area

battery is low.

 

 

 

 

 

W d Speed / Wind

Battery in the wind sensor is low.

 

Di rection Area

 

 

 

 

 

 

 

 

UVI / Barometer /

Battery in the UV / Rain sensor

 

Rainfall Area

 

is low.

 

 

 

 

 

 

BASE STATION

CHANGE DISPLAY / SETTING

To change the display and settings, use the following

buttons on the rotating dial: SELECT MEMORY / ON/OFF MODE and ALARM

In additio , the UNIT and SEARCH buttons located at the bottom of the base station allows pre-setting of the remote sensor channels and the measurement units for display.

TIP To exit from the setting mode, push any button. Alternatively, the base station will automatically exit after 30 seconds.

CLOCK RECEPTION

This product is designed to synchronize its calendar clock automatically once it is brought within range of a radio signal:

WMR100:

DCF-77 generated from Frankfurt, Germany for Central Europe

MSF-60 generated from Rugby, England

The radio signal range is 1500 km (932 miles).

WMR100A:

WWVB-60 generated from the atomic clock in Fort

Collins, Colorado

The radio signal range is 3219 km (2000 miles).

WMR100 only - slide the EU / UK switch to the appropriate setting based on your location. Press RESET whenever you change the selected setting.

The reception icon will blink when it is searching for a signal. If the radio signal is weak it can take up to 24 hours to get a valid signal reception.

indicates the status of the clock reception signal.

ICON MEANING

Time is synchronized.

Receiving signal is strong

Ti me is not synchronized.

Receiving signal is weak

To enable (and force a signal search) / disable the clock radio reception (clock synchronization):

1.Press SELECT to navigate to the Clock / Calendar /

Alarm Area. will show next to the Area.

2.Press and hold SEARCH

appears when it is enabled.

NOTE For best reception, the base station should be placed on a fl at, non-metallic surface near a window in an upper fl oor of your home. The antenna should be placed away from electrical appliances and not be moved around when searching for a signal.

7

EN