in the shipment. Power on the AirEZY 2411 BT, the LEDs on the front panel should exhibit the following patterns:

LED

Color

Light Blinking Pattern

ON

RED

Steady on

 

RX

GREEN

Steady on

TX

RED

on, when transmitting RF signal

LINK

YELLOW

Flickering when communicating over the Ethernet

 

 

port; steady-on when Ethernet connection is absent

If the yellow LED stays on continuously, then the Ethernet connection to the host computer or device is not made. Check your UTP cable and make sure that a straight-through cable is used for connecting directly to a host. A cross-over UTP cable is needed if connecting to a hub. If the yellow LED is not lit, and power is on to the device, then the Ethernet connection between the host computer and the Wireless Ethernet Adapter is correct. If one cannot communicate, and the yellow LED is off, you may want to re-position the AirEZY-2411-BT to a different location for better RF reception. You may also want to check if the unit is configured with the proper RF channel and security settings by using the Utility software.

Once the hardware is checked out to work properly with the intended host device or network equipment, the radio can be secured in the desire location by the pair of Velcro tabs.