Setting the electronic shutter
Setting the shutter mode and | Changing the shutter speed |
speed | and mode selection range |
O The SHUTTER switch is used to set the shutter speed and the shutter speed in the fixed mode.
O The shutter speed in the SYNCHRO SCAN mode can easily be changed using the SYNCHRO (“+” and
O On the SHUTTER SPEED screen of FILM (CAM) MAIN MENU 2, the setting range of the shutter speed can be restricted to the required range and whether or not to use the special operation mode (SYNCHRO SCAN) can be selected.
1 Following the steps for “Switching the display mode” (page 46), set DISP MODE to “2” or “3” on the VF DISPLAY screen of FILM (CAM) MAIN MENU 2.
2 Press the SHUTTER switch from ON to SEL.
The current shutter setting appears on the setting change message display area of the viewfinder screen.
Example: “1/120,” “50.0%,” etc.
SHUTTER switch
3 Press the SHUTTER switch to the SEL position again, and repeat this until the desired mode or speed is displayed.
When all the modes and speeds are displayed, the display will change in the sequence shown below. When the required shutter speed and mode have been assigned beforehand, only the assigned speed or mode will be displayed.
On the SHUTTER SPEED screen of FILM (CAM) MAIN MENU 2, the setting range of the shutter speed can be restricted to the required range and whether or not to use the special operation mode (SYNCHRO SCAN) can be selected.
1 Perform the menu operations (pages 84 to 86), and display the “SHUTTER SPEED” screen.
n< SHUTTER SPEED > |
|
SYNCHRO SCAN 1 | :ON |
SYNCHRO SCAN 2 | :OFF |
POSITION 1 | :ON |
POSITION 2 | :ON |
POSITION 3 | :ON |
POSITION 4 | :ON |
POSITION 5 | :ON |
POSITION 6 | :ON |
2 Turn the JOG dial button to move the arrow (cursor) to the desired item.
3 Press the JOG dial button to set the item to be changed.
Turn the JOG dial button to select ON or OFF, and press the button to enter the setting.
4 Press the MENU button to exit the menu operations.
The setting menu is cleared, and the displays showing the unit’s current statuses appear at the top and bottom of the viewfinder screen.
<Notes>
O When operating the unit from the
O For details on selecting the engineer mode and display screens, refer to “Menu operations” (pages 84 to 86).
Fixed mode
POSITION1
POSITION2
POSITION3
POSITION4
POSITION5
POSITION6
SYNCHRO SCAN 2 SYNCHRO SCAN 1
56