114
Menu Sub menu Parameter 1 Parameter 2 Parameter 3 Parameter 4
Turn F1 to select. Turn F2 to select. Turn F3 to select. Turn F4 to select. Turn F5 to select.
SYSTEM Format Parameter Mode 16:9SQ
1/16 Setting range 1080/59.94i, 1080/50i,
720/59.94p, 720/50p,
480/59.94i, 576/50i
On, Off
Default value 1080/59.94i Off
System Parameter BusMode LCD-BL EditEN Protcol
2/16 Setting range A/B,
PGM/PST On, Off On, Off GVG-A, GVG-B,
P/TCont, P/TDirt
Default value PGM/PST On On GVG-A
CamCTL1 Parameter Signal CTL Tally
3/16 Setting range IN1 to 8 1 to 5, None Enable, Disable
Default value Disable
CamCTL2 Parameter Signal PosCont Speed Power
4/16 Setting range IN1 to 8 PanTilt, Zm/Focs Fast, Middle, Slow On, Off
Default value PanTilt Fast On
Button Parameter USER1 USER2 FTB
5/16 Setting range PinPPVW,
DSKPVW, EditEN,
GPIEN, OSD,
StrFM1, StrFM2
PinPPVW,
DSKPVW, EditEN,
GPIEN, OSD,
StrFM1, StrFM2
FTB, KEYAuto,
Disable
Default value PinPPVW DSKPVW FTB
GPI Parameter GPI1 GPI2 GPIEN
6/16 Setting range AUTO, CUT,
DSK, PinP, FTB,
BGDAUTO,
BGDCUT,
KEYAUTO,
KEYCUT
AUTO, CUT,
DSK, PinP, FTB,
BGDAUTO,
BGDCUT,
KEYAUTO,
KEYCUT
On, Off
Default value AUTO DSK On
Initial Parameter Init
7/16 Setting range
Alarm Parameter Power Fan
8/16 Setting range Alarm, NoAlarm Alarm, NoAlarm
Default value
NetWork1 Parameter IP Address Save
9/16 Setting range 0 to 255 0 to 255 0 to 255 0 to 255
Default value 192 168 0 1
NetWork2 Parameter Subnet Mask Save
10/16 Setting range 0 to 255 0 to 255 0 to 255 0 to 255
Default value 255 255 255 0
NetWork3 Parameter Gateway Save
11/16 Setting range 0 to 255 0 to 255 0 to 255 0 to 255
Default value 0 0 0 0
NetWork4 Parameter MAC Address
12/16 Display only
8. Setting menu table