Menu settings
The GAIN information appears first when the OPERATE switch is set to ON.
When the MENU button is pressed, the display changes in the sequence shown below, after which the display returns to the gain setting screen.
Z Gain setting
GAIN 0dB
R:0 B: 0
;
Z Pedestal setting
PEDESTAL T: 0
R:0 B: 0
;
Z DTL setting (when SCENE FILE is set to the USER mode)
DETAIL H DETAIL
15
Z DTL setting (when 1, 2 or 3 is set for SCENE FILE)
The gain of the camera selected by the CAM CONTROL button is set on this display.
The analogue
The R gain and B gain settings are shown on the bottom line.
When the R or B GAIN dial is turned, the R or B gain is incremented or decremented. The value which can be set differs depending on the camera concerned.
The values corresponding to white balance A and B can be stored in the memory. When the automatic adjustment mode (ATW among the ATW, A and B buttons) has been selected for the white balance, “– –
The pedestal of the camera selected by the CAM CONTROL button is set on this display.
The total pedestal setting is shown on the top line, and the R pedestal and B pedestal settings on the bottom line.
When the R or B PED dial is turned, the R or B pedestal is incremented or decremented. The value which can be set differs depending on the camera concerned.
ENGLISH
DETAIL
HIGH
;
Z Camera settings
(Camera setting items)
;
Z Remote operation panel settings
(ROP settings)
;
Z LCD off
The horizontal detail and vertical detail of the camera selected by the CAM CONTROL button is set on these displays.
When USER is selected for SCENE FILE, any value from 0 to 63 can be set as the H DETAIL and V DETAIL level. Press the CONT switch to switch between H and V.
When 1, 2 or 3 is set for SCENE FILE, use the CONT dial to switch between HIGH and LOW.
4Camera settingsThe detailed settings of the camera selected by the CAM CONTROL button are set on these displays.
Turn the CONT dial to select the setting item, and press it to display the settings on the bottom line. If the CONT dial is turned while the setting is displayed, the setting can be changed. Upon completion of the setting, press the CONT dial to clear the bottom line display, and another setting item can now be selected.
(LCD off) | 5Remote operation panel settings |
| The controller settings are set on these displays. |
| Operation is the same as that for “4 Camera settings”. |
| 6Exiting the setting menu |
| Press the MENU button to exit the setting menu. |