AW-RC400
AW-PH400
AW-RP400
AW-RL400
Models AW-RP400, AW-RC400 only
Safety precautions
This class A digital apparatus complies with Canadian ICES-003
1 indicates safety information
Safety precautions
IMPORTANT SAFETY INSTRUCTIONS
Operating precautions
Contents
Safety precautions
Accessories
≥ Do not use the units outdoors ≥ Maintenance
Operating precautions
≥ Turn off the power before connecting or disconnecting the cables
≥ Handle the units carefully
Wire mounting screws with flat washers, spring washers
Accessories
Precautions for use
Introduction
AW-PH400
Installation precautions
Indoor Pan/Tilt Head AW-PH400
Parts and their function
Indoor Pan/Tilt Head AW-PH400
Parts and their function
K L M N O P
A LENS I/F 2 connector LENS I/F
E ND/EXT connector ND/EXT
@ SDI IN connector SDI IN
B OPTION connector OPTION
L SDI connector SDI
J Y connector Y
K 1394 connector
M G/L IN connector G/L IN
For installation on the ceiling
Installation Be sure to ask your dealer to install the unit
For a stand-alone installation
$ Assembling the pan/tilt head
Indoor Pan/Tilt Head AW-PH400
3 Mounting the tally lamp
Installation Be sure to ask your dealer to install the unit
AW-PH400
For installation on the ceiling
$ Setting the mounting direction switch
For stand-alone installation
Installation Be sure to ask your dealer to install the unit
≥ Web card support IP/IEEE switch IP 422/IP switch IP
$ Setting the PCB switches
≥ Analog/SDI support IP/IEEE switch IEEE 422/IP switch
≥ IEEE1394 card support IP/IEEE switch IEEE 422/IP switch
For a stand-alone installation
$ Installing the pan/tilt head
Installation Be sure to ask your dealer to install the unit
For installation on the ceiling
For a stand-alone installation
$ Mounting the camera
Installation Be sure to ask your dealer to install the unit
For installation on the ceiling
≥ Camera AW-E650, AW-E350
$ Attaching the wire
≥ Camera AW-E750
Installation Be sure to ask your dealer to install the unit
$ How to install the battery
$ Replacing the battery
$ How to remove the battery
Replacing the consumable parts
Ambient operating temperature 32F to 113F 0C to +45C
Specifications
Power consumption
Storage temperature
MEMO
AW-PH400
Plug D-SUB 15-pin for tally/INCOM system
Zoom switch
Pan/Tilt Control Panel AW-RP400
Rack-mounting adaptors
$ Front panel
1EXT CONT M/S switch
3 OPERATE OFF/ON switch
= ? @ A B C D
= ZOOM indicator
PAN POSITION indicator
IRIS indicator
FOCUS indicator
B MEMORY button
C PRESET MEMORY selection buttons 1 to
L PAN/TILT lever/ROTATION control switch
D LCD panel
O TALLY/INCOM connector
M EXT CONT IN/OUT connectors
N CAMERA CONTROL IN FROM RCB P1 to P5 connectors
$ Rear panel
S MONI SEL OUT connector
P REMOTE connector
R CONTROL OUT TO PAN/TILT HEAD P1 to P5 connectors
T CAMERA CONTROL IN FROM ROP connector
Pan/Tilt Control Panel AW-RP400
Menu settings
$ Operation method
AW-RP400 P/T CONTROL PANEL
PRIORITY MASTER/SLAVE
$ List of menu items and settings
Setting
Menu item
PRESET SPEED setting 1 to
TILT RANGE setting 190/300 degrees
SPEED WITH ZOOM POS. setting OFF/1/2/3
IRIS CONTROL setting BOTH/RP400/CB400
NOT USE / DEF / WIP / HEATER/FAN / LAMP / OPTION / ND / EXT / AF
OPTION SWITCH A to H settings
MEMORY LENGTH setting 60s/120s/300s/600s
Menu settings
AUTO RUN setting START No., END No., INTERVAL
CONTROL SELECT MODE setting INTERLOCK/UN-INTERLOCK
BUZZER setting OFF/ON
SD CARD setting
Pan/Tilt Control Panel AW-RP400
How to mount the AW-RP400 in a rack
Accessory mounting screws M4!8 mm 4 pcs
AW-RP400
Pan/Tilt Control Panel AW-RP400
How to change the position of the connector panel
Before changing the position, turn off the power
4 Secure the zoom switch using the four screws
How to replace the zoom switch
Before replacing the zoom switch, turn off the power
RP400-AW
Replace them if they are not working properly
The joysticks and zoom switch are consumables
Ask your dealer to do the replacement work
Replacing the consumable parts
Input/output connectors
Input connectors
Output connectors
Switch functions
Introduction
Cable Compensation Unit AW-RC400
Accessories
Rack-mounting adaptors
3 Cable length setting switches 0 to
1 Power LED
2 POWER switch
6 SHORT/LONG selector switch
= Pr/C IN connectors 1 to
MONITOR1, 2 connectors
Y/VIDEO IN connectors 1 to
Pb IN connectors 1 to
AW-RC400
How to mount the AW-RC400 in a rack
Cable Compensation Unit AW-RC400
DC 12.0
Power consumption Approx. 9 W
Ambient operating temperature
Specifications
AW-RL400
Pan/tilt head connecting cable
Accessories
Introduction
1 Rotary ring 2 Camera mounting screw U1/4”-20UNC
6 Pan/tilt head connector
Roll Unit AW-RL400
3 Camera mounting plate A B
AW-RL400
Installation
Roll Unit AW-RL400
Roll unit Rotary arm
Installation
When the AW-E750, AW-E650 or AW-E350 is used as the camera
When the AW-E655 is used as the camera
Roll Unit AW-RL400
Roll Unit AW-RL400
Installation
OPTION connector Lens cable Pan/tilt head connecting cable
AW-RL400
Approx. 24 W
Pan/tilt head connector
DC 24
Performance
Connections
Connections
Pan/tilt head/camera control signals
Monitor switching signals
Camera cable supplied with AW-PH400
Pan/Tilt Control Panel
Example of system configuration
Cable provided with AW-CB400
Remote
Now proceed with the settings for the AW-RP400 pan/tilt control panel
Operating procedures
$ Turning on the power
Make these adjustments using the AW-RC400 cable compensation unit
Waveform monitor composite signals
Waveform monitor component signals
$ Providing cable compensation for the cameras
$ Tracing memory settings
$ Genlock adjustments for the respective cameras
$ Video adjustments for the cameras
Perform these settings on the AW-RP400 pan/tilt control panel
Playing the tracing memory data
Operating procedures
Changing the tracing memory data
$ Setting the preset memory data
Registering the preset memory data
Erasing the tracing memory data
Playing the preset memory data
Operating procedures
10336-52F0-008 made by Sumitomo 3M
Cable specifications
When an IAS, WAS or VAS lens analog drive made by Canon is used
10336-52F0-008 made by Sumitomo 3M
When an IASD, WASD or VASD lens digital drive made by Canon is used
Cable specifications
10336-52F0-008 made by Sumitomo 3M
When an RD lens made by Fujinon is used
Cable specifications
Page
Page