Panasonic CW-XC125HU, CW-XC105HU Ventilation, Air Direction, How to Secure the Drain Pipe

Models: CW-XC125HU CW-XC105HU

1 36
Download 36 pages 8.02 Kb
Page 7
Image 7
Additional controls and important information.

Additional controls and important information.

Ventilation

The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions.

When fresh air is necessary in the room, set the ventilation lever to the OPEN position.

The damper is opened and room air is drawn out.

NOTE: Before using the ventilation feature, and prior to installing the front grille, pull down part Ventilation until level with part Air Direction.

Air Direction

CLOSE • VERTICAL AIR-DIRECTION CONTROL VENT How to Secure the Drain Pipe OPEN

Part B

Part A

About

The direction of air can be controlled wherever you want to cool by adjusting the horizontal louver and the vertical louver.

VERTICAL AIR-DIRECTION CONTROL

HORIZONTAL AIR-DIRECTION CONTROL

Controlled

Controlled by Remote

manually

Controller

The vertical air direction is adjusted

The horizontal air direction is adjusted by

by rotating the horizontal louver

rotating the vertical louver right or left manually

forward or backward manually.

or by Remote Controller.

How to Secure the Drain Pipe

In humid weather, excess water may cause the BASE PAN to overflow. To drain the water, remove the DRAIN CAP and secure the DRAIN PIPE to the rear hole of the BASE PAN. Press the drain pipe into the hole by pushing down and away from the fins to avoid injury. (See Fig.1)

the Controls on the Air Conditioner

Optional (CW3H02502B)

1.Remove the rubber plug and slide the chassis out from the cabinet. (See Fig. 2)

2.Install the drain pan over the corner of the cabinet where you removed the plug with 4 (or 2) screws. (See Fig. 3)

3.Connect the drain hose to the outlet located at the bottom of the drain pan. You can purchase the drain hose or tubing locally to satisfy your particular needs. (Drain hose is not supplied). (See Fig. 3)

4.Select the most appropriate connection from among the figures to the right (by considering the hole of the unit) to fit drain pan to your own unit. (See Fig. 3)

5.Slide the chassis back into the cabinet. Reinstall the cabinet screws. Secure the cabinet to chassis by using screws. (See Fig. 4)

7

Drain pipe

 

 

Drain cap

 

Fig. 1

Remove the

 

 

rubber plug

 

Fig. 2

 

 

CABINET

SCREW

 

 

 

DRAIN

DRAIN HOSE

 

Inside diameter

 

PAN

 

17mm (5/8")

 

 

Fig. 3

 

 

 

 

Fig. 4

Page 7
Image 7
Panasonic CW-XC125HU, CW-XC105HU Ventilation, Air Direction, How to Secure the Drain Pipe, Optional CW3H02502B