![](/images/new-backgrounds/1184018/184018247x1.webp)
5.1.2 Connection
(Continued from the previous page.)
Can you dial | No | |
out on a CO | ||
| ||
| ||
line? |
|
Connection between the central office and the PBX:
| CAUSE |
|
| SOLUTION | ||
|
| |||||
CO line is connected to the T2/T1. | Reconnect the CO line to | |||||
|
|
|
|
|
| the T1/R1 or T2/R2 of the |
|
|
|
|
|
| telephone jack using 2- |
|
|
|
| T2 |
| |
|
|
|
|
|
| |
|
|
|
| R1 |
| conductor wiring. |
|
|
|
| T1 |
|
|
|
|
|
| R2 |
|
|
|
|
|
|
|
|
|
| CO line | PBX |
|
CO line is connected to the T2/R1.
| T2 |
| R1 |
| T1 |
| R2 |
CO line |
|
PBX |