Maintenance

TEMP and LAMP Indicators

Managing the indicated problems

If a problem should occur with the projector, the LAMP and/or TEMP indicators will inform you. Manage the indicated problems as follows.

111 Confirm the status of all indicators and projector, and switch off

the projector in proper way.

222 Find out the cause of the problem by status of the LAMP and/

 

or TEMP indicators.

Power LAMP TEMP

333

Follow the following instruction for each indication and solve

 

 

the problem.

 

444

Turn on the projector in the correct way and confirm the

 

 

indicator is not indicating a problem any longer.

 

JJ TEMP indicator

 

Illuminating red while projecting and the alert will be displayed.

 

Indicator

Flashing red and the power button is turned off automatically.

 

When the TEMP indicator is lit, the lamp might have darkened.

 

 

 

 

Adjustments can be performed but not all changes will be shown on the image.

 

Problem

The temperature inside and/or outside the projector is abnormally high.

 

Cause

The air intake and exhaust

The room temperature is

The air filter is excessively

 

The projector is located

dirty and the ventilation is

 

at high elevations (above

ports are covered.

too high.

 

 

poor.

 

1 400 - 2 700 m).

 

 

 

 

 

 

 

 

 

Turn on the projector and

 

Remove the object(s)

 

 

 

set the HIGH ALTITUDE

 

Reinstall the projector in

Clean or replace the air

 

MODE to ON.

Remedy

from the ventilation

 

a temperature controlled

filter in the proper method.

 

See “INSTALLATION” of

openings or clear around

 

 

place. See page 32.

See page 26.

 

the functional instructions

 

the projector.

 

 

 

 

 

that is in the provided CD-

 

 

 

 

 

 

 

 

 

 

ROM.

JJ LAMP indicator

Indicator

Illuminating red

Flashing red

 

 

Problem

LAMP RUNTIME has

Lamp circuit failure, abnormal function or lamp unit is damaged.

reached 1 800 hours.

 

 

 

 

Cause

The lamp unit will run out

The power is turned on

Lamp circuit failure,

 

soon and needs to be

again before the lamp unit

The lamp unit is damaged.

 

replaced.

is cooled enough.

abnormal function.

 

 

 

 

Remedy

See “Replacing the lamp

Let the lamp unit cool

Contact an Authorised

See “Replacing the lamp

down and turn on the

unit” on page 27.

Service Centre.

unit” on page 27.

 

power after 90 seconds.

 

 

 

 

 

 

 

NOTE:

 

Maintenance

•• If no problem is found or the problem remains, do not turn on the projector. Instead contact an Authorised Service Centre.

 

 

 

 

 

 

ENGLISH - 25

Page 25
Image 25
Panasonic PT-AE4000E Temp and Lamp Indicators, Managing the indicated problems, JJ Temp indicator, JJ Lamp indicator