Panasonic PT-D4000U manual Indication of lamp monitor

Models: PT-D4000U

1 68
Download 68 pages 12.62 Kb
Page 50
Image 50

Indication of lamp monitor

This projector is equipped with 3 indicators to show when a lamp needs replacement or there is an abnormal internal temperature. These lamps flash or light up to indicate a problem.

Turn the power off and follow the steps below.

 

 

 

(Power indicator)

 

 

 

Lamp 2 monitor (LAMP 2)

 

 

 

Lamp 1 monitor (LAMP 1)

 

 

 

Temperature monitor (TEMP)

Name of monitor

Lamp

Information

Checkpoint

Remedial measure

lamp

indication

 

 

 

 

 

 

• Did you turn on the

• Wait about five minutes in the

 

 

 

power when the

current status.

 

Lighting in

Warm-up status

ambient temperature

• Install the unit in a location

 

 

was low

having an ambient temperature

 

red

 

 

 

(approx. 0 °C)?

from 0 °C to 45 °C.

 

(lamp unit

 

 

 

 

 

 

ON)

High temperature

 

 

Temperature

 

 

• Remove the object that is

 

inside. (WARNING)

 

monitor

 

• Check if the

blocking the ventilation port.

 

 

 

 

 

• Move the projector to a

 

 

 

ventilation port is

TEMP

 

 

temperature of 0 ˚C to 45 ˚C

Blinking in

 

blocked.

 

 

and the humidity of 20 % to

 

red

The filter is clogged.

• Is the room air

 

80 % (no condensation).

 

(1 time)

 

temperature too high?

 

 

• Turn off the MAIN POWER

 

 

 

• Is the air filter clogged

switch using the procedure on

 

Blinking in

High temperature

with dust?

 

page 23 and clean the air filter

 

 

 

red

inside

 

(refer to page 51).

 

(2 times)

(Standby condition)

 

 

 

Blinking in

 

 

• Turn off the main power supply

 

Cooling fan has

 

(MAIN POWER) switch in the

 

red

 

 

been stopped.

 

procedure shown on page 23

 

(3 times)

 

 

 

 

and consult the distributor.

 

 

 

 

 

 

 

• Did you notice a

 

 

 

 

“REPLACE THE LAMP”

 

 

Lighting in

Indicates the time

message on the screen

• This lamp monitor lights up

 

for replacing the

when turning on the

when the lamp unit used hours

 

red

 

lamp unit.

projector power supply?

have reached 2 800 hours.

 

 

Lamp monitor

 

 

• Are lamp units

 

 

 

installed correctly?

 

 

 

 

 

LAMP1 LAMP2

 

 

• Did you turn the power

• Wait until the lamp has cooled

 

 

back on immediately

off, and then turn on the

 

 

 

 

 

 

after turning it off?

power.

 

Blinking in

Error is detected in

• Some error has

 

 

red

the lamp or lamp

arisen in the lamp

• Turn off the MAIN POWER

 

(3 times)

power.

circuit.

switch using the procedure on

 

 

 

• Check for fluctuation

page 23 and consult the

 

 

 

(or drop) in the source

dealer.

 

 

 

voltage.

 

Attention • To solve any problems that the TEMP and LAMP monitor show, first turn the power off by following the steps on pages 22, 23.

If the power indicator blinks in red (3 times), the projector has malfunctioned. Please consult your dealer.

If the power indicator flashes red (once), the lamp unit cover is not properly fitted. Check the fitting

50

of the lamp unit cover.

 

Page 50
Image 50
Panasonic PT-D4000U manual Indication of lamp monitor