Baud Rate

Select the communication speed for data transmission with a connected device from the following.

4 800/9 600/19 200 bps

Control Camera CH

It is possible to assign camera channels to the RS485 ports 1 and 2 as shown below.

[Screenshot 1]

Start operation from the "RS485 Setup" menu.

SETUP MENU

 

Maintenance

 

Recording

 

Event

Schedule

 

LIVE

 

 

 

 

 

 

 

 

 

 

 

Switcher

 

Display

 

Comm

System

 

 

 

 

 

Baud Rate

 

 

 

 

 

Camera Control

 

 

19200

 

 

 

PS.DATA Setup

 

Control Camera CH

 

SETUP

 

 

Data Bit

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

RS485 Setup

 

Parity

 

 

 

NONE

 

 

 

 

 

RS232C Setup

 

Stop Bit

 

 

 

1

 

 

 

NW Setup 1

NW Setup 2

NTP Setup

z Move the cursor to "Control Camera CH" using the arrows button (CD) and press the SET button.

[Screenshot 2]

The "Control Camera CH" pop-up window will be displayed.

 

 

SETUP MENU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maintenance

Recording

 

Event

Schedule

LIVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switcher

Display

 

Comm

 

System

 

 

 

 

 

 

 

 

Control Camera CH

 

19200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Camera

Control

 

Baud Rate

 

 

SETUP

 

 

 

 

 

 

Control Camera CH

CAMERA

 

 

 

 

PS.DATA

 

 

 

 

 

 

SetupCAMERA

TERM

8

TERM

 

 

 

 

 

 

Data

 

PORT1

 

CAM9

PORT2

 

 

 

RS485

Setup

CAM1

Parity

 

 

 

 

 

 

 

 

PORT1

 

CAM10

 

PORT2

 

 

 

RS232C

Setup

CAM2

Stop

 

 

 

 

 

PORT1

 

 

 

 

 

 

 

 

 

 

NW Setup 1

CAM3

 

 

CAM11

 

PORT2

 

 

 

NW Setup 2

CAM4

 

 

PORT1

CAM12

 

PORT2

 

 

 

CAM5

 

 

PORT1

CAM13

 

PORT2

 

 

 

NTP Setup

 

 

 

 

 

 

CAM6

 

 

PORT1

CAM14

 

PORT2

 

 

 

 

 

 

 

 

 

 

 

 

 

CAM7

 

 

PORT1

CAM15

 

PORT2

 

 

 

 

 

CAM8

 

 

PORT1

CAM16

 

PORT2

 

 

 

 

 

 

 

 

 

 

 

O K

 

CANCEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

xMove the cursor to a desired cell in the "TERM" column using the arrows button.

[Screenshot 3]

The cursor will move to the selected cell in the "TERM" col- umn.

SETUP MENU Maintenance

Recording

 

Event

Schedule

LIVE

 

 

Switcher

Display

Comm

 

System

 

 

 

 

 

 

 

Control Camera CH

 

19200

 

 

 

 

 

 

 

 

Camera

Control

Baud Rate

 

 

SETUP

 

 

Control Camera CH

CAMERA

 

PS.DATA

 

 

SetupCAMERA

TERM

8

TERM

 

 

Data

 

PORT1

 

 

CAM9

PORT2

RS485

Setup

CAM1

Parity

 

 

 

 

PORT1

 

CAM10

 

PORT2

RS232C

Setup

CAM2

Stop

 

PORT1

 

 

 

 

 

 

NW Setup 1

CAM3

 

 

CAM11

 

PORT2

NW Setup 2

CAM4

 

 

PORT1

CAM12

 

PORT2

NTP Setup

CAM5

 

 

PORT1

CAM13

 

PORT2

CAM6

 

 

PORT1

CAM14

 

PORT2

 

 

 

 

 

 

 

CAM7

 

 

PORT1

CAM15

 

PORT2

 

 

CAM8

 

 

PORT1

CAM16

 

PORT2

 

 

 

 

 

 

 

 

O K

 

CANCEL

cSelect a port by rotating the jog dial. PORT 1: Control through the RS485 port 1. PORT 2: Control through the RS485 port 2.

Repeat steps 2 and 3 to assign other camera channels to be controlled through the RS485 ports.

v Move the cursor to "OK" using the arrows button and press the SET button.

Camera channels and ports to be controlled will be assigned and the "Control Camera CH" menu will be closed.

Notes:

When you move the cursor to "CANCEL" in step 4 and press the SET button, the settings will be can- celed and the "Camera Number Setup" menu will be closed.

The assignment of camera channels will not be applied until the SET button is pressed after moving the cursor to "OK" in the step 4.

The unit number of the camera will be congruent with the camera number.

Data Bit

The data length for communication will be displayed. It is impossible to change the value for this setting.

Parity

Methods to check a transmission error at communication will be displayed.

It is impossible to change the value for this setting.

Stop Bit

Number of stop bit will be displayed.

It is impossible to change the value for this setting.

r[RS232C Setup] Settings for RS232C

Perform the following settings for RS232C.

SETUP MENU

Maintenance

 

Recording

 

Event

Schedule

LIVE

 

Switcher

Display

Comm

System

 

 

 

 

Unit Address(System)

 

 

 

 

Camera Control

 

001

 

 

PS.DATA Setup

Baud Rate

 

9600

 

 

 

Data Bit

 

 

 

8

 

 

RS485 Setup

 

 

 

 

 

Parity

 

 

 

NONE

 

 

 

 

 

 

RS232C Setup

Stop Bit

 

 

 

1

 

 

 

Retry Timing

 

OFF

 

NW Setup 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NW Setup 2

NTP Setup

Unit Address(System)

A unit address (System) is a unique number assigned to each system device. The addresses must be unique to identify system devices when connecting multiple system devices.

Numbers, "001"-"099", are to be assigned as the unit addresses for the system devices.

Baud Rate

Select the communication speed for data transmission with a connected device from the following.

9 600/19 200/38 400 bps

117

Page 117
Image 117
Panasonic WJ-HD309 manual 117, Control Camera CH, Unit AddressSystem, RS232C Setup Settings for RS232C

WJ-HD309 specifications

The Panasonic WJ-HD309 is a formidable Digital Video Recorder (DVR) designed to cater to the needs of sophisticated surveillance systems. This device stands out for its impressive array of features and robust functionality, making it ideal for applications in various sectors including retail, transportation, and public safety.

One of the main features of the WJ-HD309 is its capacity to record high-quality video at resolutions up to 4CIF. This level of detail ensures that users can easily identify subjects, read license plates, and monitor critical activities with clarity. The DVR also supports multiple video input formats, offering flexibility in terms of camera compatibility.

In terms of storage, the WJ-HD309 is equipped with a large internal hard drive, enabling extensive video storage without sacrificing performance. Users can benefit from adjustable recording modes, including continuous, scheduled, and event-triggered recording. This versatility allows organizations to optimize their storage usage according to their specific needs.

The DVR’s advanced motion detection technology plays a crucial role in minimizing false alerts and focusing on relevant events. This feature enhances the efficiency of surveillance operations by ensuring that recorded footage is both meaningful and actionable. Additionally, the WJ-HD309 provides various monitoring modes, allowing for real-time viewing through either a local display or remote access via networked devices.

Connectivity is another highlight of the WJ-HD309. It supports multiple network protocols, enabling users to access their recordings and live feeds remotely. This capability extends surveillance and monitoring to smartphones, tablets, and computers, thereby enhancing operational convenience and responsiveness. The inclusion of PTZ (Pan-Tilt-Zoom) control further enables users to manage camera angles and zoom functions seamlessly.

Durability and reliability are key characteristics of the Panasonic WJ-HD309. The unit is built to withstand the rigors of continuous operation, with features like thermal management to prevent overheating and ensure longevity. Panasonic’s commitment to security and performance is evident in this DVR model, which offers a secure environment for storing sensitive footage.

Overall, the Panasonic WJ-HD309 is a powerful DVR that combines high-definition recording, flexible storage options, advanced motion detection, and convenient connectivity. Its technical specifications and feature set make it a preferred choice for organizations looking for reliable and effective security solutions. With the WJ-HD309, users are well-equipped to enhance their surveillance operations and respond effectively to security challenges.