Paradyne 3600 Series, 3611, 3610 manual Technical Specifications, ±48 Vdc

Models: 3610 3611 3600 Series

1 53
Download 53 pages 55.35 Kb
Page 14
Image 14

COMSPHERE ±48 Vdc Central Office Power Unit

Technical Specifications

Technical specifications for the CO Power Unit (which includes one power module) are listed in Table 1-1.

Table 1-1

(1 of 2)

Technical Specifications for Central Office (CO) Power Unit

Technical Specifications

Criteria

 

 

ENVIRONMENT

 

Operating Temperature

32°F (0°C) to 122°F (50°C) (See the Installation Considerations

 

section in Chapter 2 for additional operating temperature limits.)

Relative Humidity

5% to 95% (noncondensing)

Storage Temperature

±4°F (±20°C) to 158 5F (70°C)

Shock and Vibration

Withstands normal shipping and handling

 

 

POWER REQUIREMENTS

 

CO Power Unit (with 16 fully equipped

±60 Vdc to ±40 Vdc (4.5 amps maximum)

3611 DSUs in the carrier)

 

CO Power Unit (with 16 fully equipped

±60 Vdc to ±40 Vdc (2.3 amps maximum)

3151 CSUs in the carrier)

 

CO Power Unit (with 16 fully equipped

±60 Vdc to ±40 Vdc (4.8 amps maximum)

3161 DSU/CSUs in the carrier)

 

 

 

HEAT DISSIPATION (MAX.) AT

 

±48 Vdc

 

CO Power Unit (with 16 fully equipped

160 watts (CO Power Unit efficiency is approximately 76%)

cards in the carrier)

 

 

 

PHYSICAL DIMENSIONS

 

CO Power Unit

 

Height

2.4 inches ( 6.2 cm)

Height (including air filter brackets)

3.0 inches ( 7.7 cm)

Width

16.9 inches (43.3 cm)

Depth

13.5 inches (34.6 cm)

Power Module

 

Height

2.4 inches ( 6.2 cm)

Width

8.5 inches (21.8 cm)

Depth

11.7 inches (30.0 cm)

Air Filter

 

Height

0.5 inches ( 1.3 cm)

Width

14.2 inches (36.4 cm)

Depth

5.5 inches (14.1 cm)

 

 

1-4

May 1998

3000-A2-GB41-40

Page 14
Image 14
Paradyne 3600 Series, 3611, 3610 manual Technical Specifications, ±48 Vdc