COMSPHERE ±48 Vdc Central Office Power Unit

To connect the alarm contacts to the external leads of a Modular 3611 DSU (configured for alarm forwarding):

"Procedure

1.At the rear of the carrier, plug the 6-wire modular plug end of the NMS adapter cable into the J1 connector (a 6-position modular jack) on the CO Power Unit's backplane (see Figure 2-9).

2.If there is an EIA-232 cable on the top connector (labeled EIA232/V.24) of a Modular 3611 DSU's

rear connector plate, remove the ferrite choke and the EIA-232 cable. Plug the DB25 male end of the NMS adapter cable into the top connector of the rear connector plate. Tighten the screws to hold the cable in place. Then, attach the ferrite choke to the NMS adapter cable. Plug the EIA-232 cable into the DB25 female end of the NMS adapter cable. Tighten the screws to hold the cable in place. See Figure 2-9.

Figure 2-9. Connecting an NMS Adapter Cable to a Modular 3611 DSU

When the DTE Interface is EIA-232

2-18

May 1998

3000-A2-GB41-40