Installation

Installing an SDCP

If you want to mount an SDCP and the SDCP ribbon cable is not installed, remove the CO Power Unit from the carrier and follow the instructions in the SDCP Ribbon Cable Installation section in the COMSPHERE

3000 Series Carrier Installation Manual.

If you want to mount a shared Diagnostic Control Panel (SDCP) on the carrier and the SDCP ribbon cable is installed (refer to Figure 2-8):

Procedure

1.Raise the carrier 1.5 inches above the carrier below it.

NOTE

This procedure is only used when installing an SDCP onto a carrier operating with a CO Power Unit. All other carriers use the standard SDCP installation procedure as described in the Shared Diagnostic Control Panel (SDCP) Installation section in the COMSPHERE 3000 Series Carrier Installation Manual.

(In a Paradyne COMSPHERE 72-inch cabinet (4000-B2-201), if you mount an SDCP onto a carrier operating with a CO Power Unit, then only five carriers can be installed in the cabinet instead of the usual six.)

2.Remove the power module (the left power module if there are two power modules in the CO Power Unit) by loosening the two captive screws on the front of the power module. Hold onto the power module handle and slide the power module out. Then, remove the handle on the power module by using a small Phillips-head screwdriver to loosen the screws behind the power module's faceplate.

SDCP

RIBBON

CABLE

NYLON

CABLE

TIE

SHARED DIAGNOSTIC

CONTROL PANEL

(SDCP)

 

BOTTOM

 

SCREW HOLE

TOP

497-13757-02

CAPTIVE

 

SCREW

 

Figure 2-8. Installing the SDCP

3000-A2-GB41-40

May 1998

2-15

Page 31
Image 31