Paradyne 4800 Express manual Configuration / Management / SNMP, Procedure

Models: 4800 Express

1 52
Download 52 pages 57.01 Kb
Page 40
Image 40
Configuration / Management / SNMP

4. Configuration

Configuration / Management / SNMP

SNMP access to the unit is disabled by default. The read-only community string is public, and the read-write string is private. Community strings, network management system addresses, and trap manager addresses can be set using the System/Management/SNMP screen.

Manual background Procedure

To set SNMP parameters:

1.Click on the Configuration menu tab, then click on SNMP. The System/Management/SNMP screen appears.

2. Enter new SNMP parameters as desired. Click on Apply.

4-8

July 2004

4821-A2-GN21-10