Setting Up
5-46 9161-A2-GH30-30
April 1998
Assigning OCU-DP Data Ports
Use the OCU-DP Port Assignments screen to view the status of:
HAll DS0 assignments on the Network interface
HAll DS0 assignments on the DSX-1 interface
You can also use this screen to assign OCU-DP data ports to:
HNetwork interface timeslots
HDSX-1 interface timeslots
NOTES:
You can assign OCU-DP ports to the DSX-1 interface on the 9161 Single
T1 NAM. OCU-DP port assignments on the Dual DSX APM are not
supported.
"Procedure
1. Follow this menu selection sequence:
Configuration Edit/Display
Cross Connect

OCU-DP Port Assignment

2. The OCU-DP Port Assignments screen appears. Enter one of the following
into the Assign To field:
If you want to assign to . . . Then enter . . .
Network interface timeslots Net1 or Net2
DSX-1 interface timeslots on the 9161
Single T1 NAM DSX01-1
3. Move the cursor to the next editable timeslot (underlined). Use the spacebar
or type in the desired slot and port. Repeat this step until all desired timeslots
are assigned.
4. Select Save to save the assignments, or press ESC to save and return to the
Cross Connect menu.