OK
9109 FXO
97-15643
Troubleshooting

9-11

9161-A2-GH30-30 April 1998
Voice APM Front Panel LED
The E&M, FXO, and FXS Analog Voice APMs each have 1 LED status indicator.
General Status LED
Label Indication Color What It Means
OK Power and
Operational
Status
Green ON APM has power and is operational.
OFF APM is in a local self-test, or there is a
failure.
System Alarm Relay
The 5-slot housing and the access carrier provide an alarm system relay that you
can configure to activate when an alarm condition is present. To use the system
alarm relay, you must:
See the 5-slot housing or access carrier installation instructions for
information on how to connect the alarm relay connector.
Set the following configuration option:
Main Menu
Configuration Edit/Display

Alarm Options

System

Alarm Relay

Enable

Ensure that the System Alarm Relay Cut-off under the Control branch is not
selected. This menu selection turns off the system alarm relay.