Troubleshooting
9-15
9161-A2-GH30-30 April 1998

Table 9-1. ASCII Alarm Messages (3 of 5)

Message PriorityWhat To DoWhat It Indicates
month/day/year
hours:minutes:seconds
A DDS Network Failure
code has been received at
OCU-DP port in slot
ss
port
p
.
A DDS network failure
is being detected on
the specified OCU-DP
port.
Contact the DDS
service provider. 19
month/day/year
hours:minutes:seconds
Alarm Cleared for a DDS
Network Failure code at
OCU-DP port in slot
ss
port
p
.
Alarm condition no
longer exists. No action needed.
month/day/year
hours:minutes:seconds
An Excessive Error Rate
(EER) has been detected at
the Network 1/ Network 2
Interface.
An Excessive Error
Rate condition is
detected on the
network interface.
Contact network
provider. 12
month/day/year
hours:minutes:seconds
Alarm Cleared for
Excessive Error Rate
(EER) at the Network
1/Network 2 Interface.
Alarm condition no
longer exists. No action needed.
month/day/year
hours/minutes/seconds
An Excessive Error Rate
(EER) has been detected at
synchronous data port in
slot
ss
port
p
.
An excessive error
rate occurred on the
synchronous data port
for the identified slot
and port.
There is a network
problem with the
fractional portion of
the link carrying this
port’s data. Contact
network provider.
14
month/day/year
hours:minutes:seconds
Alarm Cleared for
Excessive Error Rate
(EER) at synchronous data
port in slot
ss
port
p
.
Alarm condition no
longer exists. No action needed.
month/day/year
hours:minutes:seconds
A Loss of Loop Timing has
been detected at OCU-DP
port in slot
ss
port
p
.
The specified
OCU-DP port cannot
recover timing from
the received signal on
the local loop.
Check that the CPE
CSU/DSU rate
matches the OCU-DP
rate.
20
month/day/year
hours:minutes:seconds
Alarm Cleared for Loss of
Loop Timing at OCU-DP
port in slot
ss
port
p
.
Alarm condition no
longer exists. No action needed.