Troubleshooting
9-14 9161-A2-GH30-30
April 1998

Table 9-1. ASCII Alarm Messages (2 of 5)

Message PriorityWhat To DoWhat It Indicates
month/day/year
hours:minutes:seconds
Continuous Loss Of Signal
(LOS) condition detected at
the Network 1/Network 2
Interface or at DSX-1
Interface in slot
ss
port
p
.
LOS condition
detected. 1. Check the cable to
the Network/DSX-1
interface.
2. Contact network
provider.
2 (Net)
3 (DSX-1)
month/day/year
hours:minutes:seconds
Alarm Cleared for Loss Of
Signal (LOS) condition at
the Network 1/Network 2
Interface or at the DSX-1
Interface in slot
ss
port
p
.
Alarm condition no
longer exists. No action needed.
month/day/year
hours:minutes:seconds
Continuous Out Of Frame
(OOF) detected at the
Network 1/Network 2
Interface or at DSX-1
Interface in slot
ss
port
p
.
An out-of-frame
condition is detected
at the specified
Network or DSX-1
interface.
1. Ensure that the line
framing format
configuration option
setting matches the
setting of the
equipment (DSX-1)
or network (Net).
2. Contact network
provider.
4 (Net)
5 (DSX-1)
month/day/year
hours:minutes:seconds
Alarm Cleared for Out of
Frame (OOF) condition at
the Network 1/Network 2
Interface or at the DSX-1
Interface in slot
ss
port
p
.
Alarm condition no
longer exists. No action needed.
month/day/year
hours:minutes:seconds
Continuous Out of Frame
(OOF) condition at
synchronous data port in
slot
ss
port
p
.
A continuous
out-of-frame condition
occurred on the
synchronous data port
for the identified slot
and port.
1. Ensure that EDL is
enabled on the
far-end port. Refer
to the
Technical
Reference
for
setting
configuration
options.
2. There is a network
problem with the
fractional portion of
the link carrying this
port’s data. Contact
network provider.
13
month/day/year
hours:minutes:seconds
Alarm Cleared for Out Of
Frame (OOF) condition at
synchronous data port in
slot
ss
port
p
.
Alarm condition no