Setting Up
5-33
9161-A2-GH30-30 April 1998

Table 5-7. OCU-DP Options – Slot ss Port p Options (2 of 3)

Port Rate
Possible Settings: 56K, 64KCC, Switched_56
Default Setting: 56K
Selects the rate for the port.
Port Rate only appears if Port Status is set to Enable.
56K – The setting for 56 kbps.
64KCC – The setting for 64 kbps Clear Channel.
Switched_56 – The rate for 4-wire Switched 56.
Loopback Detection
Possible Settings: Enable, Disable
Default Setting: Enable
Determines whether the the T1 access unit will detect loopback activation codes coming
from the network.
Loopback Detection only appears if Port Status is set to Enable.
Enable – Loopback code detection is enabled.
Disable – Loopback code detection is disabled.
Loss of Signal Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
Determines whether an ASCII alarm will be generated when a Loss of Signal condition
is detected.
Loss of Signal Alarm only appears if Port Status is set to Enable.
Enable – An alarm is generated when a Loss of Signal condition is detected on the
interface.
Disable – Alarms are not generated for a Loss of Signal condition.
Abnormal Station Code Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
Determines whether an ASCII alarm will be generated when an Abnormal Station code
is received from the network.
Abnormal Station Code Alarm only appears if Port Status is set to Enable.
Enable – An alarm is generated when an Abnormal Station Code is received from the
network.
Disable – Alarms are not generated when an Abnormal Station Code is received.