Troubleshooting

9-37

9161-A2-GH30-30 April 1998
Procedure
To force signaling:
1. Follow this menu selection sequence:
Main Menu
Test
Voice Port Tests
2. Enter the desired slot and port number.
3. Press PgDn to go to page 2.
4. Enter the desired setting for each field.
5. Highlight Start under Command in the row to send a test. Then, press Return
to start the test.
6. View the length of time that the test has been running in the Results column.
7. Highlight Stop under Command to stop the test.
Procedure
To monitor signaling:
1. Follow this menu selection sequence:
Main Menu
Test
Voice Port Tests
2. Enter the desired slot and port number.
3. Press PgDn to go to page 2.
4. Look at the values displayed under the Monitor Signaling portion of the
screen.
OCU-DP Tests
The OCU-DP tests run on the OCU-DP APM’s ports. The procedure to send a
Latching loopback differs from the procedure to start/stop other loopbacks. Both
procedures are described below.

Sending a Latching Loopback

Procedure
To send a Latching Loopback:
1. Follow this menu selection sequence:
Main Menu
Test
[OCU-DP Tests]
2. Enter the loopback type:
For Local: CSU or DSU
For Remote: CSU, DSU, or OCU
3. Select the code Up or Down.
4. Highlight Send in the Command row. Then, press Return to start the test. The
code will be sent for up to 10 seconds, or until an acknowledgement is
received.
5. View the length of time that the test has been running in the Results column.
6. Send the Down code to stop the loopback.