Setting Up
5-16 9161-A2-GH30-30
April 1998
Table 5-2. DSX-1 Interface Options (3 of 3)
Alarm Indication Signal (AIS)
Possible Settings: Enable, Disable
Default Setting: Enable
Specifies whether an alarm message is generated when an alarm indication signal
condition is detected on the DSX-1 interface.
Enable – Generates an ASCII alarm message.
Disable – Does not generate an ASCII alarm message.
Yellow Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
Specifies whether an alarm message is generated when a yellow alarm condition is
detected on the DSX-1 interface.
Enable – Generates an ASCII alarm message.
Disable – Does not generate an ASCII alarm message.
Configuring Ports
Configure the following ports on the T1 NAM and any APMs that are installed in
your system.
Sync Data ports on the T1 NAM or the Sync Data APM
Voice ports on the FXS, FXO and E&M APMs
Once you have a port configured, you can copy that configuration to other ports
of the same type (see
Copying Port Configurations
on page 5-35).

Configuring Sync Data Ports

Use the Synchronous Data Port Options to configure the synchronous data
port(s) on the T1 NAM or on any Sync Data APM associated with the NAM (see
Table 5-3).
Configuration Edit/Display
Sync Data Ports
NOTE:
If the selected Synchronous Data Port is disabled, Disable appears on the
screen. No other options are shown.
The Synchronous Data Port Options screen appears for Port 1 of the first slot
containing a Sync Data APM. If desired, enter the slot and port number of
another sync data port.