SmartNode 4520 & 4110 Series User Manual

1 • General information

 

 

Ports descriptions

The SmartNode 4110 Series rear panel ports are described in table 3.

 

 

Table 3. Rear panel ports

 

 

 

Port

Location

Description

 

 

 

10/100 Ethernet

Rear panel

RJ-45 connector (see figure 5 on page 16) that connects the router to an

ETH 0/0

 

Ethernet device (a cable or DSL modem, LAN hub or switch, for example).

Analog voice port,

Rear panel

FXS RJ-11(6 position, 4 wire) connectors (see figure 16 on page 32) that

FXS

 

connect the router with an analog terminal (a telephone, for example) FXO

 

 

port. EuroPOTS support (ETSI EG201 188).

 

 

 

Analog voice port,

Rear panel

FXO RJ-11(6 position, 4 wire) connectors (see figure 16 on page 32) that

FXO

 

connect the router with an analog line (FXS port). EuroPOTS support (ETSI

 

 

EG201 188).

Power

Rear panel

The gateway is available in a DC or AC power input version (see

 

 

figure 6), labeled as follows:

 

 

AC version (Internal power supply): 100–240 VAC, 50/60 Hz, 200 mA

 

 

DC version: 12 VDC, 1.25 A

 

 

 

Console

Front panel

Used for service and maintenance, the Console port (see figure 7 on page 19),

 

 

an RS-232 RJ-45 connector, connects the router to a serial terminal such as a PC

 

 

or ASCII terminal (also called a dumb terminal).

 

 

 

Reset button behavior

For those SmartNode devices that have a Reset button on the rear panel, its behavior is as follows:

To restart the unit with the current startup configuration—Press for less than 1 second and release the Reset button. The SmartNode will restart with the current startup configuration.

To restart the unit with factory default configuration—Press the Reset button for 5 seconds until the Power LED starts blinking. The unit will restart with factory default configuration.

To restart the unit in bootloader mode (to be used only by trained SmartNode technicians)—Start with the unit powered off. Press and hold the Reset button while applying power to the unit. Release the Reset button when the Power LED starts blinking so the unit will enter bootloader mode.

SmartNode Series VoIP routers overview

18

Page 18
Image 18
Patton electronic 4110, 4520 user manual Port. EuroPOTS support Etsi EG201