PB Heat DE manual Gas Piping, Natural Gas, LP Gas, 3 Pipe Capacity

Models: DE

1 43
Download 43 pages 63.1 Kb
Page 19
Image 19
Table 5.1:

GAS PIPING

Table 5.1:

Natural Gas

 

 

 

 

 

Model

 

Input

Input

 

(Cubic Ft/Hr)

(Cubic Meter/Hr)

 

 

 

 

 

 

DE-03

 

70

2.0

DE-04

 

105

3.0

DE-05

 

140

4.0

DE-06

 

165

4.7

 

 

 

 

Based on 1000 Btu/Cubic Ft.

Table 5.2:

LP Gas

 

 

 

 

 

Model

 

Input

Input

 

(Cubic Ft/Hr)

(Cubic Meter/Hr)

 

 

 

 

 

 

DE-03

 

28

0.8

DE-04

 

42

1.2

DE-05

 

56

1.6

DE-06

 

66

1.9

 

 

 

 

Based on 2500 Btu/Cubic Ft.

Table 5.3: Pipe Capacity

Capacity of pipe of different diameters and lengths in cubic feet per hour [cubic meter per hour] with a pressure drop of 0.3 inches of water [75 kPa] and a specific gravity of 0.60. No allowance for an ordinary number of fittings is required.

Pipe

³⁄₄

1

1¹⁄₄

1¹⁄₂

Length in

Feet

Pipe

Pipe

Pipe

Pipe

[Meters]

 

 

 

 

 

 

 

 

 

10 [3.0]

278 [7.9]

520 [14.7]

1050 [29.7]

1600 [45.3]

20 [6.1]

190 [5.4]

350 [9.9]

730 [20.7]

1100[ 31.1]

30 [9.1]

152 [4.3]

285 [8.1]

590 [16.7]

890 [25.2]

40 [12.2]

130 [3.7]

245 [6.9]

500 [14.2]

760 [21.5]

50 [15.2]

115 [3.3]

215 [6.1]

440 [12.5]

670 [19.0]

60 [18.3]

105 [3.0]

195 [5.5]

400 [11.3]

610 [17.3]

 

 

 

 

 

Maximum Capacity Correction Factors for Specific Gravity other than 0.60.

Specific Gravity

0.50

0.55

0.60

0.65

0.70

0.75

Correction Factor

1.10

1.04

1.00

0.96

0.93

0.90

 

 

 

 

 

 

 

Specific Gravity

0.80

0.85

0.90

1.00

1.10

1.20

Correction Factor

0.87

0.84

0.82

0.78

0.74

0.71

 

 

 

 

 

 

 

Specific Gravity

1.30

1.40

1.50

1.60

1.70

1.80

Correction Factor

0.68

0.66

0.63

0.61

0.59

0.58

 

 

 

 

 

 

 

17