If you are using a Coaxitron® controller, the control signals to operate the dome drive will be transmitted over the video coax. The
If you are not using a Coaxitron® controller, use the
Optional wiring for the Spectra II™ dome may be provided for alarm inputs (maximum of seven), relay output (Aux 1), and auxiliary output (Aux 2). For more information about wiring requirements, refer to the Back Box Connections section.
Proceed to the Back Box Installation section.
SPECTRA LITE™ INTERCONNECT BOARD
CONTROL
Figure 9. Wiring Diagram for Spectra Lite™
Table A. Video Coaxial Cable Wiring Distances
Cable Type* | Maximum Distance |
|
|
RG59/U | 750 ft (229 m) |
RG6/U | 1,000 ft (305 m) |
RG11/U | 1,500 ft (457 m) |
|
|
* Minimum cable requirements:
75 ohms impedance.
95% braided copper shield.
Pelco Manual | 11 |