CONNECTING A PTZ DEVICE, RELAY, AND ALARMS

CONNECTING A PTZ DEVICE, RELAY, AND ALARMS

The NET5301T-I incorporates a 16-pin terminal block to support the following:

PTZ device, such as a dome camera, using the Pelco P or Pelco D protocol (RS-422)

Relay control, either normally open or normally closed

Up to three alarm inputs, supervised or unsupervised, using any combination of high and low signals

The terminal block has tension clamps instead of screw terminals. Use a small screwdriver to open the clamp for a particular lead. Figure 14 shows how to wire the terminal block and connect it to the NET5301T-I.

NOTE: The terminal block is keyed. It attaches only one way to the video encoder.

PIN 1

PIN 1

 

 

 

 

 

 

 

 

 

 

 

 

PIN 9

PIN 16

Figure 14. NET5301T-I Terminal Block

Table B identifies the pin assignments for the terminal block. An arrow on the rear panel identifies pin 1; on the terminal block, pin 1 is the left-most lead on the top row (refer to Figure 14).

Table B. PTZ, Relay, and Alarm Pin Assignments

 

 

 

 

 

Top Row

 

 

 

 

 

 

 

Pin

Label

 

Lead

 

 

 

 

 

 

 

1

TX-

 

RS-422 Data TX-

 

 

 

 

 

 

 

2

RX-

 

RS-422 Data RX-

 

 

 

 

 

 

 

3

 

 

 

 

 

Ground

 

 

 

 

 

 

 

 

 

 

 

 

4

 

C

 

Relay Common

 

 

 

 

 

 

 

5

RX

 

Reserved

 

 

 

 

 

 

 

6

A1

 

Alarm 1

 

 

 

 

 

 

 

7

A2

 

Alarm 2

 

 

 

 

 

 

 

8

A3

 

Alarm 3

 

 

 

 

 

 

 

Bottom Row

Pin

Label

Lead

 

 

 

 

 

 

9

TX+

RS-422 Data TX+

 

 

 

 

 

 

10

RX+

RS-422 Data RX+

 

 

 

 

 

 

11

NC

Relay Normally Closed

 

 

 

 

 

 

12

NO

Relay Normally Open

 

 

 

 

 

 

13

TX

Reserved

 

 

 

 

 

 

14

 

 

 

 

Ground

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

Ground

 

 

 

 

 

 

 

 

 

 

16

 

 

 

 

Ground

 

 

 

 

 

 

 

 

 

 