Refer to Table C when installing the PTZ device. It lists the serial port settings that the
Table C. Serial Port Options and Defaults
Setting | Options | Default |
|
|
|
Data rate | 110, 300, 1200, 2400, 4800, 9600, 19200, 38400, | 2400 |
(bits per second) | 57600, 115200, 230400 |
|
|
|
|
Data bits | 5, 6, 7, 8 | 8 |
|
|
|
Parity | None, Odd, Even | None |
|
|
|
Stop bits | 1, 2 | 1 |
|
|
|
CONNECTING A RELAY DEVICE
The
You can operate the relay interactively, during an active connection, or automatically to coincide with certain events. Typical applications include activating a door, gate or lock, or switching on lights or other electrical devices.
WARNING: Do not exceed the maximum rating of 30 VDC, 1 A.
Figure 16 shows how to wire the relay with its power source to the video encoder (refer to Table B on page 19 for the specific connector pin assignments).
LOAD:
EXTERNAL LIGHT/SIREN
FUSE
NORMALLY | COMMON (C) |
OPEN (NO) |
POWER
MAX 30 VDC, 1 A
Figure 16. Connecting a Relay Device
21 |