Pelco dx8100 manual Modifier Description, None Value to the right is not used and is disabled

Models: dx8100

1 246
Download 246 pages 50.39 Kb
Page 177
Image 177

7. In the Exception Table section, click Add. The Exceptions dialog box opens.

7b

7a

7d7c

7e

￿

Figure 154. Exceptions Dialog Box

8.In the Exceptions dialog box, do the following:

a.In the Exception Name text box, enter a name or description for the exception (up to 20 characters).

b.In the Line Item text box, enter the name of the line item (up to 20 characters). The line item entry is case-sensitive. If the transaction is displayed as all capital letters, then the line item entry must be in all capital letters.

The DVR will search for this entry anywhere in the transaction. ATM transactions do not usually contain line items. The program may display a “No data found” error message if searching ATM transactions using line items. If the line item box is left blank, it is considered found or satisfied.

c.In the Modifier drop-down box, select a modifier that further defines the line item.

A modifier must be selected before a value can be entered. If a modifier is not selected, the Value text box is unavailable.

d.In the Value box, enter the value.

The value (9999.99 maximum) is used with the modifier (above) to trigger an exception. You can use a period to separate dollars and cents, but do not use a comma between thousands and hundreds.

e.In the This Exception Effect section, do one of the following:

Accept the default display effect setting.

In the Display Effect drop-down box, select Don’t Show or Show.

9.Click OK.

10.At the Advanced page, do one of the following:

• Click Apply to confirm selection and remain in the Device Configuration dialog box.

• Click OK to confirm selection and return to the Port/Device page.

 

Table AW. ATM/POS Exception Modifiers

 

 

Modifier

Description

 

 

None

Value to the right is not used and is disabled.

 

 

>

Greater than: Trigger exception only if the value found on the line is greater than the value entered in the Value text box.

 

 

<

Less than: Trigger exception only if the value found on the line is less than the value entered in the Value text box.

 

 

=

Equal to: Trigger exception only if the value found on the line is equal to the value entered in the Value field.

 

 

!=

Not equal to: Trigger exception only if the value found on the line is not equal to the value entered in the Value field.

 

 

C2630M-B (4/08)

177

Page 177
Image 177
Pelco dx8100 manual Modifier Description, None Value to the right is not used and is disabled