MOUNTING

The FT82011/FR82011 module can be mounted into a rack or can be used as a stand-alone module. As a stand-alone module, the unit can be placed on a desktop or can be mounted to a wall.

NOTE: As a matter of convenience, it is recommended that you set the modes of operation for the 10BASE-T/100-BASE-TX port—if required—before mounting the FT82011/FR82011 module into a rack or onto a wall. For information about setting the port modes of operation, refer to the Setting 10BASE-T/100BASE-TX Port Modes of Operation section.

MOUNTING THE FT82011/FR82011 MODULE INTO A RACK

The FT82011/FR82011 module can be installed into an RK5000 Series rack mount chassis, which can be mounted into an industry-standard 19-inch (48.26 cm) equipment rack. The RK5000 Series rack mount chassis includes the following models:

RK5000PS-3U and RK5000-3U:Designed to accommodate fiber optic modules as follows:

The RK5000PS-3U rack mount chassis provides 12 single-width module slots and a power supply.

The RK5000-3U rack mount chassis provides 14 single-width module slots (a power supply is not included). Power to the modules can be supplied using the optional external power supply (EPS5000-120).

For additional information, refer to the RK5000PS-3U/RK5000-3U Fiber Rack Mount Chassis Installation manual.

RK5000PS-5U:Designed to accommodate Enduramodules but can also accommodate fiber optic modules with the use of the appropriate adapter kit. The RK5001-1UEXP adapter kit is required for installation of the FT82011/FR82011 module into the RK5000PS-5U chassis.

For information about the RK5000PS-5U chassis, refer to the RK5000PS-5U Rack Mount Chassis Installation manual.

MOUNTING THE FT82011/FR82011 MODULE TO A WALL

The FT82011/FR82011 module can be mounted to a wall in the following ways:

Using the supplied wall clip for attachment of a single module to a wall. For installation instructions, refer to the Mounting the FT82011/FR82011 Module Using the Wall Clip section.

Using the optional WM5001 wall mount kits, which are designed for mounting of single-width fiber optic modules. The WM5001-3U base kit allows mounting of a single module to a wall. The WM5001-3UEXP expansion kit allows mounting of an additional module. It is recommended that a maximum of three expansion kits be used with the base kit, allowing a maximum of four single-width modules to be mounted to a wall.

NOTE: The WM5001 wall mount kits can be used with the WM5002 wall mount kits, which are designed for mounting of double-width fiber optic modules. If mounting a mix of single-width and double-width modules is desired, it is recommended that a maximum of two single-width modules and one double-width module be mounted in combination with one another.

For mounting instructions using the wall mount kits, refer to the WM5000 Series Wall Mount Kit Installation manual.