Table B. Troubleshooting with Front-Panel Indicators (Continued)

Indicator

 

 

 

 

Color

Meaning

Possible Cause

Corrective Action

 

 

 

 

 

 

 

Optic Fault LED (

) (Continued)

 

Flashing red

Ethernet link is down.

NOTE: In addition to a flashing red Optic Fault LED, the 100BASE-FX LED is red and the left RJ-45 Port Status LED (Link/Activity) LED is not lit.

Laser has shut down due to either of the following fault conditions:

Module is operating in extreme environmental conditions; for example, operating temperature is below or above recommended range as stated in the Specifications section.

Laser has reached end of life.

Ensure that module oper- ates according to operat- ing conditions stated in the Specifications section, and then cycle the power.

If problem persists, contact Product Support.