CONNECTIONS

Connections to the FT82011/FR82011 module are made on the rear panel of the unit (refer to Figure 6).

POWER/ALARM CONNECTION

FOR RACK-MOUNTED MODULE

POWER CONNECTION

FOR STAND-ALONE MODULE

FIBER OPTIC CABLE

10/100 NETWORK CABLE

Figure 6. FT82011/FR82011 Module Connections

As illustrated in Figure 6, FT82011/FR82011 connections consist of the following:

Power connection

NOTES:

A 12 VDC or 24 VAC power supply can be used to power the module when used as a stand-alone unit. A 12 VDC power supply is provided. If a 24 VAC power supply is used, the power supply must be a Listed Direct Plug-In Power Unit marked as Class 2 and rated as 24 VAC, 0.50 A (minimum output).

In extreme temperature conditions, it is recommended that an industrial-rated outdoor power supply be used.

10BASE-T/100BASE-TX connections

NOTES:

Use Category 5e or a higher category of cable to connect to a 10BASE-T/100BASE-TX port. Cable length must not exceed 328 feet (100 meters).

The 10BASE-T/100BASE-TX port is an auto MDI/MDI-X port; therefore, either a straight- through or crossover cable can be used. The port automatically detects the cable type that is used. Refer to the Appendix for RJ-45 MDI/MDI-X pinout information.