Table B. FX Mode Switch Settings

 

 

FX Mode

 

Switch Position

Mode of Operation

 

 

0

Independent A & B—Sets fiber ports A and B in nonredundant mode

(default setting).

 

 

 

 

Auto Failover, A is Primary—Sets fiber ports A and B in redundant

1

mode. Port A connects to the primary fiber link, and Port B connects to

 

the secondary fiber link.

 

 

 

Auto Failover, B is Primary—Sets fiber ports A and B in redundant mode.

2

Port B connects to the primary fiber link, and Port A connects to the

 

secondary fiber link.

 

 

3-9

Not used

 

 

MOUNTING

The FX82012 module can be mounted into a rack or can be used as a stand-alone module. As a stand- alone module, the unit can be placed on a desktop or can be mounted to a wall.

NOTE: As a matter of convenience, it is recommended that you set the modes of operation for each 10BASE-T/100BASE-TX port and the fiber failover mode—if required—before mounting the FX82012 module into a rack or onto a wall. For information about setting the 10BASE-T/100BASE-TX port modes of operation, refer to the Setting 10BASE-T/100BASE-TX Port Modes of Operation section. For information about setting the fiber failover mode, refer to the Setting Fiber Failover Mode section.

MOUNTING THE FX82012 MODULE INTO A RACK

The FX82012 module can be installed into an RK5000 Series rack mount chassis, which can be mounted into an industry-standard 19-inch (48.26 cm) equipment rack. The RK5000 Series rack mount chassis includes the following models:

RK5000PS-3U and RK5000-3U:Designed to accommodate fiber optic modules as follows:

The RK5000PS-3U rack mount chassis provides 12 single-width module slots and a power supply.

The RK5000-3U rack mount chassis provides 14 single-width module slots (a power supply is not included). Power to the modules can be supplied using the optional external power supply (EPS5000-120).

For additional information, refer to the RK5000PS-3U/RK5000-3U Fiber Rack Mount Chassis Installation manual.

RK5000PS-5U:Designed to accommodate Enduramodules but can also accommodate fiber optic modules with the use of the appropriate adapter kit. The RK5001-1UEXP adapter kit is required for installation of the FX82012 module into the RK5000PS-5U chassis.

For information about the RK5000PS-5U chassis, refer to the RK5000PS-5U Rack Mount Chassis Installation manual.