Troubleshooting

LED indicators on the front and rear panels of the FX82012 module allow you to monitor operational status:

LED indicators on the front panel allow you to monitor operating power, fiber redundancy mode status, 100BASE-FX port status, and optic signal/laser status. Refer to Table C for information about the front-panel indicators and associated troubleshooting guidelines.

LED indicators on the rear panel allow you to monitor RJ-45 10BASE-T/100BASE-TX port status. Refer to Table D for information about the rear-panel indicators and associated troubleshooting guidelines.

Table C. Troubleshooting with Front-Panel Indicators

Indicator Color

Meaning

Possible Cause

Corrective Action

 

 

 

 

 

Power LED (Pelco badge)

 

 

 

 

 

Blue

Power is being

No action required.

 

applied to the

 

 

 

module.

 

 

 

 

 

 

Not lit

Power is not being

Power connection is faulty.

Check power connection.

 

applied to the

 

If module is rack mounted,

 

module.

 

reseat module or power

 

 

 

supply as necessary.

 

 

 

 

 

 

Power supply has failed.

Replace power supply.

 

 

 

 

 

 

Loss of power occurs due to

Check circuit breakers, fuses,

 

 

tripped circuit breakers,

or electrical service as

 

 

blown fuses, or faulty

necessary.

 

 

electrical service.

 

 

 

 

 

 

 

 

(Continued on next page)

22

C2624M (6/07)

Page 22
Image 22
Pelco FX82012 manual Troubleshooting, Module Reseat module or power Supply as necessary, Replace power supply