Table D. Troubleshooting with Rear-Panel Indicators (Continued)

Indicator Color

Meaning

Possible Cause

Corrective Action

 

 

 

 

RJ-45 10BASE-T/100BASE-TX Port Status LED - Left (Link/Activity) (Continued)

 

 

 

 

Not lit

A 10BASE-T or

A problem may exist with

Do any of the following as

 

100BASE-TX link

the cable:

applicable:

 

cannot be

• Cable is not connected

• Connect the cable.

 

established.

 

to the module or to the

• Replace the cable. Use

 

 

10BASE-T/100BASE-TX

 

 

Category 5e or higher

 

 

compatible device.

cable.

 

 

• Cable is defective.

• Ensure that cable is proper

 

 

• Cable is not the proper

length. Cable length must

 

 

cable type.

not exceed 128 feet

 

 

• Cable is not the proper

(100 meters).

 

 

length.

 

 

 

Device connected to the

Power on the device

 

 

module is not powered on.

connected to the module.

 

 

 

 

 

 

Duplex mode setting (half-

Set the duplex mode setting

 

 

duplex or full-duplex) does

on modules to match one

 

 

not match the duplex mode

another (autonegotiation or

 

 

setting of the remote

forced half-duplex or full-

 

 

module.

duplex). Refer to the Setting

 

 

 

10BASE-T/100BASE-TX Port

 

 

 

Modes of Operation section in

 

 

 

this manual for information.

 

 

 

 

 

 

Port on module is defective.

Replace the module.

 

 

 

 

 

 

 

(Continued on next page)