If the following instructions fail to solve your problem, contact Pelco Product Support at 1-800-289-9100 or +1-559-292-1981 for assistance.

Access the properties dialog boxes for the camera on the Endura workstation (refer to the WS5000 operation manual [C2624M]). Then note the following before calling Pelco:

Unit serial number: on the product label

Software version: located in the Advanced Properties window

WARNING: Do not try to repair the unit yourself. Opening it immediately voids any warranty. Leave maintenance and repairs to qualified technical personnel. Exchange the defective unit and return it for repair.

Table E. Troubleshooting the NET5308T-EXP

Problem

Possible Causes

Suggested Remedy

Unit not ready

Power turned off

Check that the power indicator is lit.

 

 

 

 

Faulty cable connections

Check all leads, plugs, contacts, and connections.

 

 

 

 

Network connectivity issues

Contact your network administrator.

 

 

 

No video transmission; USB video status

Video loss at camera

Check all camera connections. Connect local monitor and

indicator is red

 

check camera function.

 

 

 

 

Defective camera

Connect local monitor and check camera function.

 

 

 

 

NET5308T-EXP connected to

Connect USB cable to correct connector.

 

incorrect USB connector on

 

 

NET5300B rear panel

 

 

 

 

 

Defective NET5308T-EXP

Check camera on a different NET5308T-EXP.

 

 

 

Poor analog video or ghosting

Termination not set correctly

From an Endura workstation, disable video termination for

 

 

looping video; enable it if not using looping video.

 

 

 

No looping video on local monitor

Faulty cable connections

Check all leads, plugs, contacts, and connections.

 

 

 

 

Video termination is enabled

From an Endura workstation, enable video termination.

 

 

 

Unit status indicator is red

Unit fan failure

Replace the NET5308T-EXP and have it checked by Pelco.

 

 

 

 

System cannot activate the unit

Replace the NET5308T-EXP and have it checked by Pelco.

 

encoder channel

 

 

 

 

The unit is not ready for operation after

Voltage failure during programming

Replace the NET5308T-EXP and have it checked by Pelco.

firmware upload

of update file

 

 

 

 

C2655M-A (10/08)